Telco

Telecom EME Signage in Australia

Telecom EME Signage in Australia

Definitions & Abbreviations

IBS Low Power Antenna (In-Building System refer Section 5.1 of RFSCP)
Cat 1 IBC = General Public Limit not exceeding 100mm from any one antenna
Cat 2 IBC = General Public exceeding 100mm from any one antenna (treated as per Micro / Macro sites)

Macro site
Microcell site
ARPANSA
Site having General Public Limit Greater than 2m from antenna
Site having General Public Limit up to 2m from antenna
Australian Radiation Protection and Nuclear Safety Agency
EME Electromagnetic energy (aka electromagnetic radiation)
MCF Mobile Carriers Forum
MERCS MCF EME Regulatory Compliance Strategy
NSA National Site Archive
RF Radio Frequency
VESI Victorian Electricity Supply Industry

 

MERCS-1 – RF Hazard Area

MERCS-1

MERCS-1

MERCS 1 signage is used to identify RF hazard areas at all Optus macro sites including rooftop sites. Signage will be installed as per RFSCP Manual 2 requirements. In addition to RFSCP Manual 2, Optus specific requirements are listed below.

  1.  The sign requirements will be indicated on the site drawings which may refer to Optus Site Signage standard drawings OSD-170, 180, 190 & 191.
  2.  The Supplier will install this sign at all Optus greenfield sites, including rooftop sites.
  3.  The Supplier will ensure that this sign is also installed at all existing sites during siteupgrades. If the sign is missing at the required locations, the Supplier will supply and install.
  4.  The sign used will be 400mm x 350mm metal.

 

MERCS-2 – MCF Information Sign

MERCS-2

MERCS-2

MERCS 2 signage is used to direct community members to the RFNSA / Facility manager. Signage will be installed as per RFSCP Manual 2 requirements. In addition to RFSCP Manual 2, Optus specific requirements are listed below:

  1. The sign requirements will be indicated on the site drawings which may refer to Optus SiteSignage standard drawings OSD-170, 180, 190 & 191.
  2. The Supplier will install this sign at all Optus macro greenfield sites (ground sites androoftops).The Supplier will ensure that this sign is also installed at all existing sites during site upgrades; if the sign is missing at the required locations, the Supplier will supply and install.
  3. The sign installed on Rooftop sites will be in the same location as MERCS1 sign.Sign used will be 250mm x 180mm metal.
  4. The NSA site number will be entered on the sign will be either: metal stamp / punched or UV resistant black text stickers. Marker pens / texters are not permitted.

MERCS-3 – General Public RF Hazard Sign

MERCS-3

MERCS-3

MERCS 3 signage is used identify areas that exceed General public limits.Signage will be installed as per RFSCP Manual 2 requirements. In addition to RFSCP Manual 2, Optusspecific requirements are listed below.

  1.  The sign requirements will be indicated on the site drawings which may refer to Optus SiteSignage standard drawings OSD-170, 180, 190 & 191.
  2. EME boundaries, suitable barriers and sign locations will be indicated on the Site Drawings.
  3. The sign used will be 400mm x 350mm metal.

 

MERCS-4 – Occupational RF Hazard Sign

MERCS-4

MERCS-4

 

MERCS 4 signage is used identify areas that exceed Occupational limits.Signage will be installed as per RFSCP Manual 2 requirements. In addition to RFSCP Manual v2Optus specific requirements are listed below:

  1. The sign requirements will be indicated on the site drawings which may refer to Optus SiteSignage standard drawings OSD-170, 180, 190 & 191.
  2. EME boundaries, suitable barriers and sign locations will be indicated on the Site Drawings.
  3. The sign used will be 400mm x 350mm metal.

 

MERCS-5 – Transmitting Antenna Sign

MERCS-5

MERCS-5


MERCS 5 signage is used to identify transmitting antennas.Signage will be installed as per RFSCP Manual 2 requirements. In addition to RFSCP Manual v2Optus specific requirements are listed below:

  1. The sign requirements will be indicated on the site drawings which may refer to Optus Site Signage standard drawings OSD-170, 180, 190 & 191. 
  2. The sign used will be 100mm triangle shaped self-adhesive (sticker type) affixed to the backof each antenna.
  3.  The sign used to warn personnel of the presence of an overhead RF hazard will be 200mm triangular metal

 

MERCS-6 – Transmitting Microwave Sign

MERCS 6 signage is used to identify low power transmitting microwave antennas. Signage will be installed as per RFSCP Manual 2 requirements. In addition to RFSCP Manual v2 Optus specific requirements are listed below:

  1. The sign requirements will be indicated on the site drawings which may refer to Optus Site Signage standard drawings OSD-170, 180, 190 & 191.
  2. The sign used will be 200mm x 110mm, self-adhesive (sticker type).

 

MERCS-7 – Concealed Antenna Sign

MERCS 7 signage is used to identify location of concealed transmitting antennas. Signage will be installed as per RFSCP Manual 2 requirements. In addition to RFSCP Manual v2 Optus specific requirements are listed below.

  1. The sign requirements will be indicated on the site drawings which may refer to Optus Site Signage standard drawings OSD-170, 180, 190 & 191.
  2. The sign used will be 300mm x 165mm Polyprop.
  3. Consideration will be given to the placement of the sign so that is does not degrade the visualamenity of the screening, concealment or the disguise whilst also complying with RFSCP Manual 2 installation requirements.

 

MERCS-8 (A, B or C) – Microcell Signs

MERCS 8 signage is used to identify areas that exceed General Public limits at microcell sites. Signage will be installed as per RFSCP Manual 2 requirements. In addition to RFSCP Manual v2 Optus specific requirements are listed below:

  1. The sign requirements will be indicated on the site drawings which may refer to Optus SiteSignage standard drawings OSD-170, 180, 190 & 191.
  2. Preferred sign is to be 200mm x 100mm metal.
  3. Also refer to addition requirements in 6.5 Signage on Power Authority Poles.

 

MERCS-9 – In-Building Systems Sign

MERCS 9 signage is used to identify all low power transmitting antennas in almost all in-building (IBC) sites.Signage will be installed as per RFSCP Manual 2 requirements. In addition to RFSCP Manual v2 Optus specific requirements are listed below:

  1. 1. The sign requirements will be indicated on the site drawings which may refer to Optus Site Signage standard drawings OSD-170, 180, 190 & 191.
  2. No Optus specific requirements.

 

MERCS-10 – Repeater Systems Sign

 

MERCS 10 signage is used to identify all transmitting antennas at repeater sites. Antennas may be low or high power Signage will be installed as per RFSCP Manual 2 requirements. In addition to RFSCP Manual v2 Optus specific requirements are listed below :

  1. The sign requirements will be indicated on the site drawings which may refer to Optus Site Signage standard drawings OSD-170, 180, 190 & 191.
  2. No Optus specific requirements.

 

 

15 thoughts on “Telecom EME Signage in Australia

  1. Great content! Super high-quality! Keep it up! 🙂

    1. maratus says:

      Thanks for your comment

  2. Heide Billo says:

    Keep this going please, great job!

  3. Terrific work! That is the kind of information that should be shared across the net. Disgrace on Google for not positioning this publish upper! Come on over and visit my web site . Thanks =)

    1. maratus says:

      Thanks for your comment. please inform us your web site address.

  4. Paris Rehler says:

    Hi my loved one! I want to say that this post is amazing, great written and include almost all important infos. I¡¦d like to look more posts like this .

    1. maratus says:

      Thanks for your comment

  5. Hi there. I found your web site via Google at the same time as searching for a related matter, your web site got here up. It seems to be great. I’ve bookmarked it in my google bookmarks to come back then.

    1. maratus says:

      thanks for your comment

  6. Lincoln says:

    Good information. Lucky me I discovered your
    blog by accident (stumbleupon). I have bookmarked it for later!

    1. maratus says:

      Thanks for your comment

  7. Your style is unique in comparison to other people
    I have read stuff from. I appreciate you for posting when you’ve got the opportunity, Guess I will just book mark this blog.

  8. CBD says:

    Pretty! This was an extremely wonderful post. Many thanks for supplying this
    information.

  9. Superb post however I was wanting to know if you could
    write a litte more on this subject? I’d be very thankful if you could elaborate a little bit further.
    Bless you!

  10. I have learn several excellent stuff here. Definitely price bookmarking for revisiting.

    I wonder how much effort you place to make this type of
    excellent informative site.

Leave a Reply

Your email address will not be published. Required fields are marked *